GE Inspection Technologies
GE Inspection Technologies has optimized its USN 60 series for use in direct sunlight and operation at extreme temperatures. These new characteristics make the instruments ideally suited for outdoor use with its increased long battery operation time.
The combination of the rugged USN durability, 11 hours of battery operation, fast rotary knob operation, outstanding ultrasonic performance, and the モsquare wave pulserヤ form a powerful portable ultrasonic inspection tool.
Optimized outdoor use design
- Extreme temperature use (-20°C to 55°C /-4°F to 130°F)
- Easy to view in direct sunlight
- 11 hours battery operation
- Hi-resolution color LCD display produces モAnalog Look and Performanceヤ echo dynamics.
- 4 selectable vibrant display color schemes to match lighting conditions.
- Gates and gate functions are color coded for easy identification and fast adjustment.
User Preferred Features
- Simple operation with fast rotary knob adjustments; gain is always directly accessible with the left-hand rotary knob and lockable.
- Auto CAL makes calibration fast & easy.
- 15 Hz to 6 kHz (spike mode) PRF and 15 Hz to 2 kHz (square mode) PRF (pulse repetition frequency)
- 2 independent gates monitor amplitude and soundpath distance for both flaw detection and thickness measurement applications.
- 250 KHz to 25 MHz frequency range.
- RF display mode enhances signal evaluation and bond inspection of dissimilar materials.
- 4 selectable damping settings (50, 75, 150, 500 ohms) for optimum probe performance.
- 1 mm to 28 m (0.040ヤ to 1100ヤ) range (in steel) covers thin to lengthy acoustically clean materials.
- dB REF key evaluates subsequent echoes gain value and amplitude against the highest echo in Gate A (reference echo) when activated.
- IF (Interface) Gate Option for automatic start of the display, Gate A, Gate B, and / or DAC / TCG for immersion testing applications.
- VGA Output Option provides an easy way to connect to a PC monitor or PC projector for viewing by large audiences or training purposes.
- RF Output Option outputs the raw RF waveform via a standard Lemo connector for further analysis.
- BEA (Backwall Echo Attenuator) Option allows independent gain control of the region under Gate B for backwall echo monitoring.
- 19ヤ Rack Mount Model.
Wide range of applications
A 6 kHz pulse repetition frequency, real-time analog and TTL outputs makes the USN 60 flaw detectors series ideal for a wide range of automated systems testing applications. The exclusive SmartView feature displays even the shortest echoes for critical scanning and rotating part inspections.
The quality, durability, dependability and ease of use that you have come to expect of Krautkramerメs popular USN Series of instruments remains. From rugged field inspections to high resolution thin measurements, long acoustically clean materials, and immersion systems, the USN 60 flaw detector family extends the range of applications that a portable instrument can perform. Furthermore the selectable 450V Square Wave Pulser satisfies a wide range of tough-to-penetrate applications, such as difficult to penetrate metallic applications and especially non-metals inspection like composite materials.
Tools for easy weld inspection
- Color Leg allows easy identification of leg and skip distances for weld inspection
- GRID mode dynamically changes bands of display backgroundcolors for each leg.
- A-SCAN mode dynamically changes the color for each leg of the モliveヤ A-Scan
- Weld Rating Calculation simplifies the rating of weld indications according to AWS Specification D1.1. (Formula D = A ヨ B ヨ C).
- Trigonometric flaw location function with curvature correction automatically calculates depth, surface distance, and sound path to flaw along with the leg of the inspection when using angle beam probes. All TOF measurements can be displayed in mm, inches or µs.
- SmartView function along with variable persistence freeze modes displays the most important information (relevant shot) for a test.
- Real time (single shot) analog and TTL outputs handle a wide range of automated systems applications.
- Choose from Four Freeze Modes: ALL, Peak Std, Compare or Envelope for optimum waveform evaluation and comparison.
- Three Variable Persistence Modes are selectable in Freeze Envelope to visually assist flaw detection & evaluation for scanning and moving part inspections.
- Compare frozen reference wave-forms to live A-Scans in different colors to easily interpret test results.
Documentation and recording
- Store & preview a minimum of 200 user-named data sets with A-Scans for quick recall and instrument setup.
- UltraDOC 4 software program for bi-directional communication with a PC for easy storage of data sets with A-scan and documentation of test results.
- UltraMATEル software program simplifies the transfer, storage, analysis, and documentation of thickness data.
- Reports with A-Scans are output directly to a variety of printers.
Specifications:
Range USN 60 | 0.040ヤ to 1100ヤ (1 mm to 28 m) at steel velocity; range selectable in fixed steps or continuously variable |
Material Velocity | Continuously adjustable from 0.0098 to 0.6299 inches/µs (250 to 16,000 m/s); 65 selectable material velocities |
Display Delay | -20 to 3498 µs in steel (dependent on range) |
Probe Delay/Zero Offset | 0 to 999.9 µs |
Damping | 50, 75, 150, 500 ohms |
Gain | 0 to 110 dB adjustable in selectable steps 0.1, 0.5, 1.0, 2.0, 6.0, user definable, and locked |
Test Modes | Pulse echo, dual, and thru-transmission |
Pulser | Square wave excitation pulse |
Pulse Voltage (Square wave pulser mode) | 50 to 450 V scrollable in 10 V adjustments |
Pulse Width (Square wave pulser mode) | Tunable from 50 to 1000 ns in 10 ns adjustments |
Pulse Energy (Spike mode) | Low, High |
Pulse Repetition Frequency USN 60 | Autolow, autohigh, manually adjustable from 15 to 6000 Hz (spike mode) and 15 to 2000 Hz in square wave mode, in 5 Hz increments, external trigger (spike mode only) |
Bandwidth (amplifier bandpass) | 0.25 to 25 MHz with 10 selectable settings including broadband |
Gate Monitors | Two independent flaw gates controllable over entire sweep range |
Measurement Modes | Zero-to-first, multi-echo with selectable flank or peak detection |
Rectification | Positive halfwave, negative halfwave, fullwave, RF |
Reject (suppression) | 0 to 80% linear |
Units | Inch, millimeter, or microsecond selectable |
Operating Temperature | -20° to 55°C (-4° to 130°F); -25° to 70ºC (-13° to 158 º F ) storable |
Languages | Selectable English, German, French, Spanish, Italian, Portuguese, Norwegian, Swedish, Finnish, Danish, Dutch, Russian, Czech, Romanian, Slovakian |
Probe Connectors | BNC or Lemo |
Keypad | International symbols |
Battery Power | Lithium Ion battery pack; NiMH, NiCad or alkaline cells substitutable |
Battery Life | 11 hours on Li-Ion battery pack |
Size | 11.1ヤ W x 6.75ヤ H x 6.25ヤ D (282 x 171 x 159 mm) |
Display | 640 x 480 pixels Color LCD 132.48 x 99.36 mm |
Weight | 6.6 lbs. (3.0 kg) Li-Ion battery; 3.5 lbs.(1.6 kg) without battery |
Color Leg | Easy identification of leg and skip distances for angle beam inspection in A-scan or grid background colors |
Weld Rating Calculation | Simplifies the rating of weld indications according to AWS specification D1.1, (formula D=A-B-C) |
Dust Proof/DrippingWater Proof | As per IEC 529 specification for IP54 classification |
Compliance | EMC/EMI: EN 55011:2007, EN 61000-6-2:2005 Ultrasound: EN 12668, ASTM E317 |
What's In The Box:
(1) Lithium-ion battery pack, 12 Ah, in battery lid
(1) Power supply/charger unit
(1) Protective screen foil
(1) Operating manual
(1) CD-ROM with application for firmware upgrade download
(1) Manufacturer’s certificate
What's In The Box:
(1) Lithium Ion Rechargeable Battery Pack
(1) Lithium Ion Battery Charger /AC Power Supply
(1) SD Card (2 GB)
(1) USB Download Cable
(1) Transport Case
(1) Quick Reference Operating Card
(1) Operating Manual on CD
(1) Certificate Of Conformity
Mentor UT is the first ultrasonic testing device to easily allow wireless connectivity and live streaming, so inspectors can get real-time second opinions when they need them. That same wireless cloud connectivity enables Mentor UT to remotely generate comprehensive inspection reports on users’ desktops with the click of a button.
User-defined menus can walk technicians through every step of any inspection - from probe selection and calibration to reporting - ensuring consistency across your inspections, every time, from every inspector. And with the flexibility to load multiple workflows on one device, you can guarantee easy access to the right apps for any inspection.
Highlights
Benefits
Conveniently upload & analyze your inspection data on your computer
User-defined menus walk technicians through every step of any inspection
Flexibility to load multiple workflows on one device
Remote communication between experts and inspector
Features
Remote calibration-capable
High-performance design
Rugged durability
Intuitive operation
Applications
Customize or create inspection “apps” for your unique testing procedures, industry applications, and experience levels
Mentor UT Features
Mentor UT was designed around user needs. Its intuitive glove-friendly touch screen and a durability rating of IP65allow for more accurate and efficient inspections, under any industrial conditions.
Perform inspections confidently using Mentor UT’s powerful 32:32 phased array flaw detector (upgradable to 32:128)with conventional UT channel and 18kHz pulse repetition frequency (PRF).
Ensure that UT inspections are performed consistently every time by custom-tailoring workflows (apps) to guide users through the calibration and inspection process step by step. On-board wireless connectivity and data export capabilities streamline one-touch reporting and analysis (offline analysis software included).
On-demand live support empowers inspectors to make on the spot maintenance decisions anywhere, anytime.
Mentor UT also features unmatched probe versatility. Choose from commonly found Tyco or Ipex probe connection options, or industry-standard Phasor-style connector for improved probe compatibility.
This device also easily pairs with Waygate Technologies' industry-leading dual-element linear DM probes for corrosion inspection, linear array probes for weld testing and composite inspection, as well as a wide variety of commercially available scanners.
Included :
1 Each Case For Main Unit (1 OF 5)
1 Each GE Brand Pouch
1 Each 32:32PR Phased Array Flaw Detector, 1024 Laws, 8 Groups, 10Hz-20kHz PRF, 0-78dB Gain, 16 Points TCG
1 Each Shoulder Strap
1 Each Hand Strap
1 Each AC ADAPTER E119932-C AWM 2464 300V 16AWG VW-1
2 Each Battery Pack for GE Mentor Unit
1 Each Battery Charger
1 Each Mentor Software, Manual, & Quick Start Guide
1 Each Cover for Phased Array Flaw Detector
1 Each 5MHz Scanner for Mentor UT Phased Array Flaw Detector, 32 Elements, 1.5mm Pitch, Corrosion Mapping
1 Each GENE-DMCABLE_3M_TOP | MODULAR PROBE (S/N 19J02D55)
1 Each MODULAR PROBE(S/N 19KOOURD)
1 Each S/N 19H0003M 32:128PR Array Add-On for Mentor UT Phased Array Flaw Detector
1 Each (2 OF 5) CASE FOR 100N3901
2 Each (3 OF 5)(4 OF 5) PLASTIC CASES
1 Each Pelican 1400 (5 of 5)
1 Each Powercord for SPU65-105 Ac Adapter ROHS Compliant 10A 125V
Also you can check : Used GSSI StructureScan Pro SIR 4000 Control Unit - Sale !!
GE Phasor XS 16:64 Phased Array Ultrasonic Flaw Detector
The GE Phasor XS brings the proven advantages of Phased Array technology to a new – and accessible – level. This portable and rugged device combines the value of Phased Array with a codecompliant conventional UT flaw detector. It is simple to use, easy to learn and specially designed with practical, relevant features.
When used in Phased Array mode, the operator can electronically control multiple beams from one probe. The precise beam control including angle, focus and size, results in improved probability of detection (POD) and sizing. With one scan from one contact location, greater area is covered and comprehensive data can be viewed in real time on a full color sector display. When compared to conventional Ultrasonic inspection, the productivity and cost savings from the Phasor XS are easily measured.
Productivity gains
When the inspection requires a different angle with conventional ultrasonic testing, the operator must change his probe and re-visualize the integration of the new information. A different time base and sensitivity level is represented. Although this is not a problem for the skilled operator, it takes time. Through the power of Phasor XS, these inefficiencies are drastically minimized.
Real time color imaging from the Phasor XS supplies an integrated cross-sectional visualization of the part originating from multiple angles. A single A-Scan can also be selected for display in combination with the image. With a single probe, you can achieve more than ever before – and in less time!
Overall, the Phasor XS provides:
- Improved area coverage, faster results
- More information from one scan of the part
- Better recorded result from the generation of an image
- One probe replicates the capabilities of many conventional UT probes and wedges
- Time and cost savings from reduced hours evaluating indications with multiple angles
Measurable time savings!
Some weld inspections require a complete scan with three separate angles. Using the Phasor XS can result in a time savings of two thirds!
Test quality improvements
Defect orientation is a prediction made in the development of a test procedure and an inspection angle is chosen based on this prediction. Beam spread is chosen purposely broad to account for some level of error in the prediction, so essentially it is a compromise.
With the Phasor XS, electronic control of the beam allows test procedures to be developed that will yield higher Probability of Detection (POD), in the same inspection time, by allowing the choice of an ideal beam over the full inspection area. The quality of the scan is improved and the Phasor XS’ full-color, real time sector display with selectable A-Scan supplies the standard accepted method for instant and reliable sizing.
Simple change over
Building Phased Array capabilities into a successful proven operating platform ensures the transition to Phased Array inspection will be cost effective. Phasor XS’ simple menu driven operation of basic Phased Array controls puts the technology within reach of the Level II field inspector. Data is easily interpreted and the cost of training is minimal.
Standard Features
An on board data set memory is combined with removable storage via an SD card for documentation and setup storage. This ensures your operators will be working with consistent setups to get brilliant results that you can see later on the screen or computer
The unique Sector Freeze mode allows review and storage of all the A-Scans behind the image. Select your beam of interest from all of the shots for separate display and improve your sizing with focal and angle control.
- Combined Phased Array and code compliant Conventional UT flaw detector
- Truly portable Phased Array – less than 4 kg (7 lbs)
- Electronically controlled and selectable beam angles, focus and size
- Simultaneous inspection with multiple beams from a single location
- Full color, real time sector display with a selectable ASCAN
- Fullscreen Bscan plus Display reverse and flip
- Rugged packaging to withstand heavy onsite use
- Snap shot image storage of sector images and ASCANS
- Dialog probes 16/64
- Delay law calculator
- Push button control for operation in a bag
- Simple operating scheme
- Image transfer via SD card
Specifications:
Display Size Resolution | 6.5” VGA (640*480 pixel) color TFT, 60Hz refresh rate |
Battery Type | Custom Li-Ion battery pack (3S6P configuration) |
Battery Life | 4 hours minimum |
Battery Charging | External charger that connects directly to the battery pack |
External Power Supply | Universal input (85 – 265V / 50 – 60 Hz) |
Units of Measure | inch and mm |
SD Card Memory | Sealed compartment |
Number of Cycles Focal Laws | Conventional Channel: 1 Phased Array Channels: 128 (max) |
Pulse repetition frequency | Conventional Channel: 15 to 2000Hz Phased Array Channels: 15 to 7680Hz |
Pulser Type | Conventional Channel: Spike Phased Array Channels: Bipolar Squarewave |
Pulser Voltage | Conventional Channel: 300V (max) Phased Array Channels: /-25V to /-75V |
Pulser Energy | Conventional Channel: Low, High Phased Array Channels: n/a |
Pulser Rise Time | Conventional Channel: <15ns Phased Array Channels: Not Specified |
Damping | Conventional Channel: 50, 500 and 1000 Phased Array Channels: n/a |
Dual Mode | Conventional Channel: Off and On Phased Array Channels: n/a |
Receiver input Capacitance | Conventional Channel: <50pF Phased Array Channels: |
Maximum input voltage | Conventional Channel: 40Vp-p Phased Array Channels: |
Bandwidth / Amplifier bandpass | Conventional Channel: 0.3 to 15MHz(-3dB points) Phased Array Channels: 0.5 to 10MHz |
Direct Documentation Format | Conventional Channel: JPEG Phased Array Channels: JPEG |
Probe Connections | Conventional Channel: 00 Lemo/ BNC Adaptor Supplied Phased Array Channels: Custom Supplied |
Physical Probe | Conventional Channel: n/a Phased Array Channels: 1 to 64 |
Virtual probe | Conventional Channel: n/a Phased Array Channels: 1 to 16 |
Number of Cycles | Conventional Channel: 1 Phased Array Channels: 1 to 128 |
Pulser Width (1/2 Cycle) | Conventional Channel: n/a Phased Array Channels: 40 to 500ns |
Pulser Delay | Conventional Channel: n/a Phased Array Channels: 0 to 10.24us |
Receiver Delay | Conventional Channel: n/a Phased Array Channels: 0 to 10.24us |
Receiver Input Resistance | Conventional Channel: 1000ohm (dual mode) Phased Array Channels: 220ohm |
Analog Gain | Conventional Channel: 0 to 110.0dB Phased Array Channels: 0 to 40.0dB |
Digital Gain | Conventional Channel: n/a Phased Array Channels: 0 to 50.0dB |
Frequency Select | Conventional Channel: 2.25MHz, 5MHz, LP and HP Phased Array Channels: 2.25MHz, 5MHz, LP and HP |
Rectification | Conventional Channel: PosHW, NegHW and Fullwave Phased Array Channels: PosHW, NegHW and Fullwave |
Measurement Resolution | Conventional Channel: 5nsec Phased Array Channels: 5nsec |
Displayed Readings | Conventional Channel: A%A, A%B, SA/, SA^, SB/, SB^ Phased Array Channels: A%A, A%B, SA/, SA^, SB/, SB^ |
VGA output | Conventional Channel: Yes Phased Array Channels: Yes |
SD Card Memory | Conventional Channel: Yes Phased Array Channels: Yes |
RS 232 interface | Conventional Channel: Yes Phased Array Channels: Yes |
Auto Timebase Calibration | Conventional Channel: Yes Phased Array Channels: No |
Reject | Conventional Channel: 0 to 80% Phased Array Channels: 0 to 80% |
TCG | Conventional Channel: 16 points (max) - 6dB/usec Phased Array Channels: 16 points (max) - 6dB/usec |
Sound Velocity | Conventional Channel: .0393 - .5905”/us[1000 – 15000m/s] Phased Array Channels: .0393 - .5905”/us[1000 - 15000m/s] |
Range | Conventional Channel: 5m @ steel shear velocity Phased Array Channels: 1m @ steel shear velocity |
Weight | Conventional Channel: 7.5lbs (with batteries) Phased Array Channels: 7.5lbs (with batteries) |
Size | Conventional Channel: 11.1”W x 6.75”H x 6.25”D (282 x 171 x 159mm) Phased Array Channels: 11.1”W x 6.75”H x 6.25”D (282 x 171 x 159mm) |
Display Delay | Conventional Channel: 2.5m @ steel shear velocity Phased Array Channels: 1m @ steel shear velocity |
Gates | Conventional Channel: A, B Phased Array Channels: A,B,IF |
Gate Threshold | Conventional Channel: 5% to 95% Phased Array Channels: 5% to 95% |
Gate Start | Conventional Channel: [0.1mm to 2m] Phased Array Channels: 0.1mm to 1m |
Gate Width | Conventional Channel: [0.1mm to 2m] Phased Array Channels: 0.1mm to 1m |
Gate Modes | Conventional Channel: Off, Pos, Neg[Off, Coincidence, Anticoincidence] Phased Array Channels: |
TOF Modes | Conventional Channel: Flank, Peak Phased Array Channels: Flank, Peak |
Scan type | Conventional Channel: n/a Phased Array Channels: Linear or Sector |
Data visualization refresh rate | Conventional Channel: 60Hz Phased Array Channels: 60Hz |
Available views | Conventional Channel: Ascan Phased Array Channels: Ascan only, Image only, Ascan Image |
Dialog Languages | Conventional Channel: English, Spanish, German, French, Chinese, Japanese Phased Array Channels: English, Spanish, German, French, Chinese, Japanese |
Environmental tests | |
Cold Storage | -20C for 72 hrs, 502.4 Procedure I |
Cold Operation | 0C for 16 hrs, 502.4 Procedure II |
Heat Storage | 70C for 48 hrs, 501.4 Procedure I |
Heat Operation | 55C for 16 hrs, 501.4 Procedure II |
Damp Heat / Humidity | 10 Cycles: 10hrs at 65C down to 30C, 10 hrs at 30C up to 65C, Transition within 2 hrs, 507.4 |
Temperature Shock | 3 Cycles: 4 hrs at –20C up to 70C, 4 hrs at 70C, Transitions within 5 minutes, 503.4 Procedure II |
Vibration | 514.5-5 Procedure I, Annex C, Figure 6, General exposure: 1hr each axis |
Shock | 6 cycles each axis, 15g, 11ms half sine, 516.5 Procedure I |
Loose Cargo | 514.5 Procedure II |
Transit Drop | 516.5 Procedure IV, 26 drops |
IP54 / IEC529 Dust Proof / Dripping water proof as per IEC 529 | |
Environmental sealing tests | IP54 / IEC529 … Dust Proof / dripping water proof as per IEC 529 specifications for IP54 classification Enviromental op temp Low battery indication Amplitude variation expected over battery life Graticule Architectural suppression Linearity on timebase Pulser, Voltage p to p, rise time, duration, fall time, Reverberation ampitude, frequncy spectrum plot Amplifier and attenuator |
INCLUDE :
- GE Phasor XS 16:64 Phased Array Ultrasonic Flaw Detector (BC# -L/T*)
- Battery Pack
- AC Adapter/Charger
- User Manual On Cd-ROM
- Carrying Case (G)
Weld Inspection
Trigonometric projections
AWS
DAC
DGS
Inspection of Forgings and Castings
Manual PRF adjustment
Phantom echo indicator
DGS
Inspection of Rails
High PRF (up to 2000 Hz)
Lightweight: 850 g (1.87 lb)
Small size and ergonomics
Inspection of Composites
RF Display
2 gates with B-start triggered with echo in gate A
TCG correction with high slope 120 dB/μs
Reflector depth indicated in layer
USM Go Standard Model (GEIT1480179) Kits:
ASME Weld
MWB 45° angle beam transducer, 4MHz frequency, 8x9mm element (0056927)
MWB 60° angle beam transducer, 4MHz frequency, 8x9mm element (0056928)
MWB 70° angle beam transducer, 4MHz frequency, 8x9mm element (0056929)
MSEB dual element straight beam transducer, 4MHz, 3.5x10mm element (0057462)
Right Angle Lemo #00 to Lemo #00 cable (022-509-819)
Right Angle Lemo #00 to Dual Lemo #00, KBA 533 cable (022-509-821)
AWS Weld
AWS Gamma angle beam transducer, 2.25MHz frequency, 16x19mm element (113-292-601)
AWS 45° wedge, 63x63mm element (118-340-104)
AWS 60° wedge, 16x16mm element (118-340-105)
AWS 70° wedge, 16x16mm element (118-340-106)
Right Angle Lemo #00 to BNC cable (022-509-822)
General Purpose
MB S straight beam transducer, 4MHz frequency, 10mm element (0057749)
Right Angle Lemo #00 to Lemo #00 cable (022-509-819)
Features:
USM Go comes with D-pad (arrow key) control
DMS Go thickness gauge upgrade available
LCD display, 800 x 480 pixels
Flip function allows for left or right hand use
Pulser (EN12668 specifications)
Simulated spike pulser mode
120 to 300V amplitude
Uni-polar square wave (optional)
120 to 300V with 10V steps pulser voltage
30 to 500ns with 20ns steps pulser width
50 or 1000 Ohms damping
Vibration and shock tested
IP67 dustproof & waterproof
What's In The Box:
(1) Lithium Ion "on-board" rechargeable battery
(1) Battery charger /AC power supply
(1) LCD screen protectors (10-pack)
(1) SD card (8GB)
(1) Transport case
(1) Hand strap
(1) Quick reference card
(1) Operating manual on CD
(1) Certificate of conformity
The Instrument driver for USM 35X is required to exchange data and settings between the instrument USM 35X and the software AMPLECTOR Instrument Manager. All versions are supported USM 35X, USM 35X DAC, USM 35X S, USM 35X SD and instrument options (DAC/TCG, DGS, Data Logger with 3rd gate).
Instrument data supported by the Instrument driver USM 35X: Instrument settings (ultrasonic parameters), A-scans, test results, and Data Recorder file types "Linear" and “Grid”.
Features
- Straightforward display (as in Windows Explorer) of dataset files of the USM 35X in the AMPLECTOR Instrument Manager with detailed display of the most important instrument settings (ultrasonic parameters), A-scan and measurement values with extended information parameters
- Straightforward display of Data Recorder files (as in Windows Explorer) with detailed display of Data Recorder type, statistics, as well as instrument settings and notes
- Display of instrument information (for example software version)
- Import and export of dataset files
- The thickness alarm values (lower and upper threshold of the material thickness) can be subsequently set and changed in the AMPLECTOR Instrument Manager
Requirements
- Operating system Windows Vista, Windows 7, Windows 8, Windows 8.1, Windows 10
- Microsoft .NET Framework 4.5 or higher
- Installed software AMPLECTOR Instrument Manager
- Cable with RS-232-USB adapter for the connection between the instrument and the computer (not included in the standard package)
Standard package
- Instrument driver software as download (no shipment on data media)
- No Quick Start Guide necessary
Tips for the operating and use
- The RS232-USB adapter must be set to COM 3
- The instrument must be set to data transfer rate of 57600 baud
- The AMPLECTOR Instrument Manager and the instrument driver can only display and edit the data and information from the instrument at the quality which was originally saved
- The stability and quality of communication between the AMPLECTOR Instrument Manager and the instrument are based on the transmission method of the instrument manufacturer
- AMPLECTOR Instrument Manager and the instrument driver do not support any server and remote control mode
The new ultrasonic Go platform from GE’s Inspection Technologies business combines a thickness gauge and a flaw detector in one single lightweight instrument.
Ergonomically Designed with the User in Mind
The USM Go ultrasonic portable flaw detector has been ergonomically designed to provide an instrument that is light, small and easy to use in the harshest of inspection environments
Features:
- Portability
- Small size, lightweight, robust, dust- and waterproof construction allow the instrument to be easily operated in confined spaces, areas of difficult access, and in harsh environments.
- Can be operated with one hand, leaving other hand free for other tasks, such as maintaining probe in optimum position or holding on to ladders.
- Light enough to be carried throughout a whole day’s shift.
- Battery provides up to 6 hours operation. Can be recharged on- or off-board.
- Several accessories to improve mobility are available: wrist strap, shoulder harness, belt holster.
- Easy-to-Read Screen
- A display screen that is the same size as those in other GE flaw detectors, even though the instrument is much smaller than other instruments in the range
- An 800 x 480 pixel display, which is better resolution than a standard DVD.
- A screen with an optimized aspect ratio to ensure highly defined echo separation.
- A screen that can be easily viewed, whether hand-held or desk-mounted.
- A screen that has been ergonomically sized to help reduce eyestrain.
- An integrated stand allows the user to optimize the viewing angle, when the instrument is desk- or benchmounted
- AutoGate Threshold for faster measurement with optimum accuracy.
- A-scan freeze mode function (for gate A and B) fascilitates working in difficult ergonomic conditions.
- Display measurement indicators show both amplitude and distance to reduce risk of error
- Ease of Use
- Pressure-sensitive joystick imported and adapted from the successful range of remote visual inspection and ultrasonic equipment offered by GE.
- All controls within fingertip reach. User can dedicate function keys according to preference
- A “Flip” function allows the instrument to be used equally well by left-handed and right-handed people.
- A standard USB connection to allow data to be downloaded from the flaw detector for further analysis or storage.
- The instrument’s 2 GB memory can be easily exchanged by SD cards up to 16 GB
- Reports are produced in jpeg format so there is no need for special reading software.
- Printable summary list of all parameters
- Easy directory management on SD cards
- Built-in menu customization tool allows to adapt the menu structure to two levels of users.
- Smart notes function increases reporting efficiency.
- Yearly calibration reminder for efficient quality management
Increasing Productivity
The USM Go features intuitive operation so there is virtually no time-consuming, learning curve.
You are productive from the moment you pick it up!
There is no need to refer to the manual, as clear instructions are provided as you go along. Navigation is simplified using the proven graphical user interface (GUI) and the innovative joystick, allowing one-handed operation for fast and accurate adjustment.
Other features allowing increased productivity are:
- A robust molded rubber casing to withstand the harshest environments and significantly reduce downtime. The instrument is dust- and waterproof to IP67 and is tested to withstand shock and vibration
- A simple on-board data logger to collect and save thickness measurements or eventually attach the corresponding A-scan image.
- Backwall Echo Attenuator (BEA) helps to find very small defects improving detectability.
- Automatic Gate Threshold for the 2 gates ensuring accurate measurements made under the same conditions
- Video recording upto 8 minutes allows live reporting.
- State-of-the-art electronics, including digital amplification, for a wide range of application benefits.
- A wide Pulse Repetition Frequency range allows use at low PRF to inspect forged parts without any “ghost” echoes and to inspect welds at high PRF when fast and regular scanning movement is required.
- Precise Time of Flight indication in µs.
- TrueDGS compatible.
- Customized versions of the USM Go are also available, specially adapted to meet specific inspection codes or applications. For example, an optional square wave pulser can be supplied for applications involving the inspection of highly attenuative material. The versions shown in the table are currently available. For more detailed information, please contact your local GE representative or visit www.ge-mcs.com.
A Wide Range of Applications
The USM Go has been designed to provide flaw detection capability in inspection situations throughout the industrial and process spectrum, from aerospace to power generation and from the automotive sector to the oil and gas industry.
These include:
Weld Inspection:
- Trigonometric projections
- AWS
- DAC
- DGS
- Manual PRF adjustment
- Phantom echo indicator
- DGSS
- Backwall Echo Attenuator (BEA)
- High PRF (up to 2000 Hz)
- Lightweight: 850 g (1.87 lb)
- Small size and ergonomics
- RF Display
- 2 gates with B-start triggered with echo in gate A
- TCG correction with high slope 120 dB/µs
- Reflector depth indicated in layer
- Narrow band filters
- Low noise digital amplifier
- TCG correction with high slope 120 dB/µs
- Backwall Echo Attenuator (BEA)
LCD Display | |
Active Area | W x H: 108 mm x 64.8 mm (4.25” x 2.55”) |
Screen Diagonal | 5.0” |
Pixel Resolution | W x H: 800 x 480 pixels |
Connectors | |
Probe Connectors | Two LEMO-00 |
UT Output Connector | SAP output, alarm |
USB Interface | Micro USB connector |
SD Card Connector | Full size SD card slot to accommodate standard SD cards |
Pulser - All pulser measurements taken according to EN12668 specifications | |
Pulser Mode | Simulated spike standard, uni-polar square wave optional |
Pulser Voltage (SQ Mode) | 120 V to 300 V with 10 V steps |
Pulser Width (SQ Mode) | 30 ns to 500 ns with 20 ns steps |
Pulser Amplitude (Spike Mode) | Low : 120 V High: 300 V |
Damping | 50 or 1000 Ohms |
PRF | Automatically optimized between 15 Hz to 2000 Hz, 3 automatic adjustment modes : AutoLow, AutoMed, AutoHigh - Manual Control of PRF from 15 to 2000 Hz |
Receiver | |
Range | 14016 mm at steel longitudinal wave (557”) |
Digital Gain | Dynamic range of 110 dB, with 0.2 dB step |
Analog Bandwidth | 0.2 MHz - 20 MHz |
Filters | Broad band Narrow band filters 1; 2; 2.25; 4.5; 10; 13; 15 MHz |
Gate | |
Independent Gates | 2 Gates (A and B), Gate B can support triggering by Gate A |
Rectification | Full Wave (FW) Positive (POS) RF Negative (NEG) |
Measurement | Peak, Flank, JFlank |
Measurement units | TOF in, mm, µs Amplitude % dB |
Memory | |
Capacity | 2 GB SD card. Up to 16 GB memory cards can be used |
Report | Jpeg and BMP reports |
Data Logger | Option for thickness or A-scan recording, compatible with UltraMATE |
Environmental | |
Battery | 6 hours battery life On board charging Off board charging with optional adaptor Proportional battery gauge indicating remaining operation time Automatic energy server mode (Auto Off) allows saving battery life by putting the instrument in sleep mode automatically when not in use |
Charger | “Universal” AC (100-240 V, 50-60 Hz) Meets CCC, CE, UL, CSA and PSE requirements |
Size | 175 mm x 111 mm x 50 mm (6.8” x 4.3” x 1.9”) |
Weight | 845 g (1.87 lb) with the battery |
Languages | Bulgarian, Chinese, Czech, Dutch, English, French, German, Hungarian, Italian, Japanese, Portuguese, Polish, Russian and Spanish |
Protection as per Mil-Std-810F | |
Damp Heat and Humidity (Storage) | 10 cycles: 10 hrs at 60°C (140°F) down to 30°C (86°F), 10 hrs at 30°C (86°F) up to 60°C (140°F), transition within 2 hrs, 507.4 |
Temperature Shock (Storage) | 3 cycles: 4 hrs at –20°C (-4°F) up to 60°C (140°F), 4 hrs at 60°C (140°F), transitions within 5 minutes, 503.4 Procedure II |
Vibration | 514.5-5 Procedure I, annex C, figure 6, general exposure: 1 hr each axis |
Shock | 6 cycles each axis, 15 g, 11 ms half sine, 516.5 Procedure I |
Loose Cargo (In Shipping Container) | 514.5 Procedure II |
Transit Drop (Packaged for Shipment) | 516.5 Procedure IV, 26 drops |
Operating Temperature Range | 0°C to 55°C (32 to 131°F) |
Storage Temperature Range | -20°C to 60°C (-4 to 140 °F) with battery, 24 hrs |
Dustproof / Waterproof | As per IEC 529 specification for IP67 classification |
Compliance | EMC/EMI EN 55011 EN61000-6-2:2001 Ultrasound EN 12668 ASTM E1324 E317 ANSI/NCSL Z 540-1-1994 MIl STD 45662A MIL STD 2154 |
INCLUDE :
GE USM GO Ultrasonic Flaw Detector (BC# 38137-L/T*)
AC Adapter/Charger
Power Cord
USB PC Interface Cable
User Manual On CD-ROM
Carrying Case (G)
Proven performance features
of the successful Krautkramer instruments USN 50/52 were adopted or further improved:
Calibration range from 1 mm to 12 m for minimum and maximum sized workpieces
Large frequency range from 0.25 to 25 MHz for optimum probe matching
Pulse repetition frequency from 15 to 2000 Hz, automatically linked with the calibration range or manually adjustable
2-point calibration: easy, fast, and very accurate
Material tables with 65 sound velocities stored in the instrument
Even for demanding applications
Besides the powerful ultrasonic features, the USN 58L has other specialities available to extend its application range:
Real-time outputs: analog and TTL outputs for the requirements of automatic test systems
"SmartView" function: maximum flaw detectability even at high scanning speeds
Reliable display of even shorter signals (e.g. from only one transmit/ receive cycle) by adjustable persistence.
Easy operation, thanks to the two rotary knobs, is combined with an intuitive menu layout.
GE KrautKramer USN58L Ultrasonic Flaw Detector Thickness Gauge
Installed Options:
- SQPLS
- VGA Output
USN 58L features the transflective (i.e. contrast by external light) color LCD screen that even with direct sunlight, the display is still easily readable - an advantage that every operator will appreciate in field applications.
INCLUDED :
Krautkramer USN58L Ultrasonic Flaw Detector w/ Options: (BC# 38869-L/T*)
SQPLS
VGA Output Option (USN 58L Only)
(2) BNC Cables
Alkaline Battery Pack
User Manual On CD-ROM
Also you can check : Used General Electric Mentor UT Phased Array Flaw Detector - Sale !!
Krautkramer USN 58R
The ultrasonic instrument for the workshop, even for automated inspections.
High-contrast, crystal clear
Optimum readability from any viewing angle, all this is provided by the EL display of the USN 58R. This display technology does not only make this ultrasonic instrument the best choice for shop use but also for outdoor applications at very low temperatures: the USN 58R loves the cold and operates even at -20 °C / -4 °F without any problem.
It goes without saying that the display can be further optimized depending on the application site: you can set the brightness low or high, or you can choose the inverted display mode for fatigueproof work. Thanks to the electronic parallax-free grid, you will see every detail even at an unfavorable viewing angle and from a greater distance.
Automatic, multi-channel
Requirements that the USN 58R is also able to meet: the instrument is qualified for automated applications by its two monitor gates provided with configurable real-time outputs - in combination with the "SmartView" feature which ensures maximum flaw detectability, especially at high scanning speeds.
Multi-channel test systems can be quite easily set up by synchronizing several instruments and, provided with the Interface Echo option, these systems are also suitable for an immersion test. This makes the USN 58R an economic solution in this extended field of application for portable ultrasonic instruments.
Universal, flexible
The attributes characterizing the USN 58R thanks to its other options: the Backwall Echo Attenuation feature, specifically including the backwall echo in the flaw evaluation by reducing the gain, makes the USN 58R a good choice, especially for the inspection of castings and forgings.
Another focal area of application is the weld inspection - of course with amplitude evaluation and precise flaw location on flat and curved components - or with the additional options DAC/TCG or DGS for ultrasonic testing according to the majority of national or international standard specifications.
Included :
GE USN58R Ultrasonic Flaw Detector (BC# -L/T*)
BNC To BNC Cable
User Manual On CD-ROM
Carrying Case (G)
GE Inspection Technologies has optimized its USN 60 series for use in direct sunlight and operation at extreme temperatures. These new characteristics make the instruments ideally suited for outdoor use with its increased long battery operation time.
The combination of the rugged USN durability, 11 hours of battery operation, fast rotary knob operation, outstanding ultrasonic performance, and the モsquare wave pulserヤ form a powerful portable ultrasonic inspection tool.
Optimized outdoor use design
- Extreme temperature use (-20°C to 55°C /-4°F to 130°F)
- Easy to view in direct sunlight
- 11 hours battery operation
- Hi-resolution color LCD display produces モAnalog Look and Performanceヤ echo dynamics.
- 4 selectable vibrant display color schemes to match lighting conditions.
- Gates and gate functions are color coded for easy identification and fast adjustment.
User Preferred Features
- Simple operation with fast rotary knob adjustments; gain is always directly accessible with the left-hand rotary knob and lockable.
- Auto CAL makes calibration fast & easy.
- 15 Hz to 6 kHz (spike mode) PRF and 15 Hz to 2 kHz (square mode) PRF (pulse repetition frequency)
- 2 independent gates monitor amplitude and soundpath distance for both flaw detection and thickness measurement applications.
- 250 KHz to 25 MHz frequency range.
- RF display mode enhances signal evaluation and bond inspection of dissimilar materials.
- 4 selectable damping settings (50, 75, 150, 500 ohms) for optimum probe performance.
- 1 mm to 28 m (0.040ヤ to 1100ヤ) range (in steel) covers thin to lengthy acoustically clean materials.
- dB REF key evaluates subsequent echoes gain value and amplitude against the highest echo in Gate A (reference echo) when activated.
- IF (Interface) Gate Option for automatic start of the display, Gate A, Gate B, and / or DAC / TCG for immersion testing applications.
- VGA Output Option provides an easy way to connect to a PC monitor or PC projector for viewing by large audiences or training purposes.
- RF Output Option outputs the raw RF waveform via a standard Lemo connector for further analysis.
- BEA (Backwall Echo Attenuator) Option allows independent gain control of the region under Gate B for backwall echo monitoring.
- 19ヤ Rack Mount Model.
Wide range of applications
A 6 kHz pulse repetition frequency, real-time analog and TTL outputs makes the USN 60 flaw detectors series ideal for a wide range of automated systems testing applications. The exclusive SmartView feature displays even the shortest echoes for critical scanning and rotating part inspections.
The quality, durability, dependability and ease of use that you have come to expect of Krautkramerメs popular USN Series of instruments remains. From rugged field inspections to high resolution thin measurements, long acoustically clean materials, and immersion systems, the USN 60 flaw detector family extends the range of applications that a portable instrument can perform. Furthermore the selectable 450V Square Wave Pulser satisfies a wide range of tough-to-penetrate applications, such as difficult to penetrate metallic applications and especially non-metals inspection like composite materials.
Tools for easy weld inspection
- Color Leg allows easy identification of leg and skip distances for weld inspection
- GRID mode dynamically changes bands of display backgroundcolors for each leg.
- A-SCAN mode dynamically changes the color for each leg of the モliveヤ A-Scan
- Weld Rating Calculation simplifies the rating of weld indications according to AWS Specification D1.1. (Formula D = A ヨ B ヨ C).
- Trigonometric flaw location function with curvature correction automatically calculates depth, surface distance, and sound path to flaw along with the leg of the inspection when using angle beam probes. All TOF measurements can be displayed in mm, inches or µs.
- SmartView function along with variable persistence freeze modes displays the most important information (relevant shot) for a test.
- Real time (single shot) analog and TTL outputs handle a wide range of automated systems applications.
- Choose from Four Freeze Modes: ALL, Peak Std, Compare or Envelope for optimum waveform evaluation and comparison.
- Three Variable Persistence Modes are selectable in Freeze Envelope to visually assist flaw detection & evaluation for scanning and moving part inspections.
- Compare frozen reference wave-forms to live A-Scans in different colors to easily interpret test results.
Documentation and recording
- Store & preview a minimum of 200 user-named data sets with A-Scans for quick recall and instrument setup.
- UltraDOC 4 software program for bi-directional communication with a PC for easy storage of data sets with A-scan and documentation of test results.
- UltraMATEル software program simplifies the transfer, storage, analysis, and documentation of thickness data.
- Reports with A-Scans are output directly to a variety of printers.
Specifications:
Range USN 60 | 0.040ヤ to 1100ヤ (1 mm to 28 m) at steel velocity; range selectable in fixed steps or continuously variable |
Material Velocity | Continuously adjustable from 0.0098 to 0.6299 inches/µs (250 to 16,000 m/s); 65 selectable material velocities |
Display Delay | -20 to 3498 µs in steel (dependent on range) |
Probe Delay/Zero Offset | 0 to 999.9 µs |
Damping | 50, 75, 150, 500 ohms |
Gain | 0 to 110 dB adjustable in selectable steps 0.1, 0.5, 1.0, 2.0, 6.0, user definable, and locked |
Test Modes | Pulse echo, dual, and thru-transmission |
Pulser | Square wave excitation pulse |
Pulse Voltage (Square wave pulser mode) | 50 to 450 V scrollable in 10 V adjustments |
Pulse Width (Square wave pulser mode) | Tunable from 50 to 1000 ns in 10 ns adjustments |
Pulse Energy (Spike mode) | Low, High |
Pulse Repetition Frequency USN 60 | Autolow, autohigh, manually adjustable from 15 to 6000 Hz (spike mode) and 15 to 2000 Hz in square wave mode, in 5 Hz increments, external trigger (spike mode only) |
Bandwidth (amplifier bandpass) | 0.25 to 25 MHz with 10 selectable settings including broadband |
Gate Monitors | Two independent flaw gates controllable over entire sweep range |
Measurement Modes | Zero-to-first, multi-echo with selectable flank or peak detection |
Rectification | Positive halfwave, negative halfwave, fullwave, RF |
Reject (suppression) | 0 to 80% linear |
Units | Inch, millimeter, or microsecond selectable |
Operating Temperature | -20° to 55°C (-4° to 130°F); -25° to 70ºC (-13° to 158 º F ) storable |
Languages | Selectable English, German, French, Spanish, Italian, Portuguese, Norwegian, Swedish, Finnish, Danish, Dutch, Russian, Czech, Romanian, Slovakian |
Probe Connectors | BNC or Lemo |
Keypad | International symbols |
Battery Power | Lithium Ion battery pack; NiMH, NiCad or alkaline cells substitutable |
Battery Life | 11 hours on Li-Ion battery pack |
Size | 11.1ヤ W x 6.75ヤ H x 6.25ヤ D (282 x 171 x 159 mm) |
Display | 640 x 480 pixels Color LCD 132.48 x 99.36 mm |
Weight | 6.6 lbs. (3.0 kg) Li-Ion battery; 3.5 lbs.(1.6 kg) without battery |
Color Leg | Easy identification of leg and skip distances for angle beam inspection in A-scan or grid background colors |
Weld Rating Calculation | Simplifies the rating of weld indications according to AWS specification D1.1, (formula D=A-B-C) |
Dust Proof/DrippingWater Proof | As per IEC 529 specification for IP54 classification |
Compliance | EMC/EMI: EN 55011:2007, EN 61000-6-2:2005 Ultrasound: EN 12668, ASTM E317 |
What's In The Box:
(1) Lithium-ion battery pack, 12 Ah, in battery lid
(1) Power supply/charger unit
(1) Protective screen foil
(1) Operating manual
(1) CD-ROM with application for firmware upgrade download
(1) Manufacturer’s certificate
The AutoSigma 3000 gives accurate operation in an easy to use package that is both light and rugged. Designed for operator convenience, the lightweight, battery powered unit is easy to carry and easy to hold during inspections. The 500kHz frequency allows inspection of thin materials using the standard probe. The 60kHz setting is the aerospace industry standard.
APPLICATIONS
- Identification and separating of non-ferrous (typically aluminum alloys) components
- Validation of in-service heat damage
- Verification of heat treatment
- Measurement of the density of powder metal parts
- High accuracy 0.8 to 110% IACS (0.45-64 MS/m) conductivity measurement /- 0.1 at 10% IACS
- Light weight at only 0.4kg
- Temperature compensation (0 to 40-deg C)
- Selectable Frequency (60 or 500 kHz)
- Clear Display with Back Light
- Data Logging (500 readings in up to 50 files)
Includes :
47P001 Conductivity Probe (60 and 500kHz)
Straight Probe with 0.50 Inch Tip Diameter
Conductivity Set-up Block
AA Alkaline Batteries (3 ea.)
Probe Lead (60 inch)
Probe Shoe for Radiused Surface
Plastic Carrying Case
Carrying Bag with Shoulder Strap
Operating Manual
Certificate of Conformity
- 1