The result of over 10 years of proven leadership in modular NDT test platforms, the OmniScan MX has been the most successful portable and modular phased array test instrument produced by Olympus to date, with thousands of units in use throughout the world.
$7,190.00
Qty:

The result of over 10 years of proven leadership in modular NDT test platforms, the OmniScan MX has been the most successful portable and modular phased array test instrument produced by Olympus to date, with thousands of units in use throughout the world.

Olympus now offers a new PA module with TOFD, a new UT module, as well as new software programs (NDT SetupBuilder and new OmniPC version) that expand the capabilities of the successful OmniScan MX2 platform and improve the workflow efficiency of nondestructive testing inspections.

Building on a Solid Basis

This second generation OmniScan MX2 increases testing efficiency, ensuring superior, advanced AUT application performance with faster setups, test cycles, and reporting, in addition to universal compatibility with more than 10 phased array and ultrasound modules. Designed for NDT experts, this high-end, scalable platform delivers true next-generation NDT performance.

The OmniScan MX2 offers a high acquisition rate and new powerful software features for efficient manual and automated inspection performance—all in a portable, modular instrument.

OmniScan_MX2_2010_04.psd

Faster Is Better!

Powerstart your day with the OmniScan MX2. The OmniScan MX2 simplifies and speeds up the setup process with its intuitive step-by-step Wizard, so you can start testing quickly. Featuring the industry-standard phased array user interface with faster-than-ever performance, a bigger and brighter 10.4 in. (26.4 cm) screen, new and unique intuitive touch-screen capabilities, and faster data transfer, the MX2 enables you to get to your next inspection quicker.

OmniScan MX2

More than an Instrument-A Solution Provider

The OmniScan MX2 is an important part of your inspection solution, and can be combined with other critical components to form a complete inspection system. Olympus offers a complete product range that includes phased array probes, scanners, analysis software, and accessories, all of which are integrated and packaged into rapidly deployable, application-specific solutions for a quick return on your investment. In addition, Olympus offers a high-quality global calibration and repair service, backed by a team of phased array application experts to ensure that you get the support you need.

Pressure Vessel Weld Inspection

Pressure Vessel Weld Inspection
A complete inspection of pressure vessel welds can be performed in a single scan using an OmniScan PA and manual scanner such as the HSMT series or a motorized scanner like the WeldROVER. By combining TOFD and PA in a single inspection pass, a significant reduction in inspection time can be achieved as compared with conventional raster scanning or radiography. Furthermore, inspection results are available immediately, enabling you to detect problems with welding equipment and fix them right away.

Composite Inspection

Composite Inspection
Parts made of laminate composite materials pose an inspection challenge due to their various shapes and thicknesses.
Olympus offers complete solutions for the inspection of carbon-fiber-reinforced polymer structures. These solutions are based on the OmniScan flaw detector, the GLIDER™ scanner, and dedicated probes and wedges designed for CFRP flat panel and radius inspection.

Weld Inspection of Small-Diameter Pipes

Weld Inspection of Small-Diameter Pipes
When coupled with the COBRA manual scanner, the OmniScan flaw detector is capable of inspecting pipes ranging from 0.84 in. OD to 4.5 in. OD. With its very slim design, this manual scanner is able to inspect pipes in areas with limited access. Adjacent obstructions such as piping, supports, and structures can be as close as 12 mm (0.5 in.).

Corrosion Mapping Inspection

Manual and Semiautomated
Corrosion Mapping

The OmniScan PA system with the HydroFORM scanner is designed to offer the best inspection solution for detecting wall-thickness reductions resulting from corrosion, abrasion, and erosion. In addition, this system detects mid-wall damage, such as hydrogen-induced blistering and manufacturing-induced delamination, and clearly differentiates such anomalies from loss-of-wall-thickness.
For this application, phased array ultrasound technology offers superior inspection speed, data point density, and detection.

Modular Instrument

A Platform that Evolves as your Needs Grow

Designed to secure both your current and future phased array investments, the OmniScan MX2 houses more than 10 different Olympus modules. You can be confident that you will get the most out of your investment as specifications will continue to evolve with your needs through constant software updates.

State of the Art PA2 and UT2 Modules

As a world leader in phased array technology, Olympus has released a new line of modules compatible with MX2 instrument.

PA2

The new phased array offer-led by the new innovative PA2 modules, features multiple improvements, such as:

Best Phased Array and TOFD Signal Quality Ever

  • Better signal-to-noise ratio
  • More powerful pulsers
  • 64 pure gray tone

More Multi-group Capabilities

  • Ability to use PA and UT channels simultaneously

General Hardware Improvements

  • Higher operating temperatures (45 °C)
  • New OmniScan probe connector with quick latch system
  • Designed for IP66 environmental rating
  • Extended autonomy on batteries
PA Module
16:64 PA2
16:128 PA2
32:128 PA2
32:128PR PA2

UT2

The new conventional ultrasound module features the same UT-channel technology as the PA2 modules, but offers twice as many channels.

UT Module
2 ch. UT2


OmniScan MX2 Mainframe Specifications

GeneralOverall dimensions (W x H x D)325 mm x 235 mm x 130 mm (12.8 in. x 9.3 in. x 5.1 in.)
Weight3.2 kg (7 lb), no module and one battery
Data StorageStorage devicesSDHC card*, most standard USB storage devices, or fast Ethernet.
*Lexar® brand memory cards are recommended for optimized results.
Data file size300 MB
I/O PortsUSB ports3
Audio alarmYes
Video outputVideo out (SVGA)
Ethernet10/100 Mbps
I/O LinesEncoder2-axis encoder line (quadrature, up, down, or clock/direction)
Digital input4 digital TTL inputs, 5 V
Digital output4 digital TTL outputs, 5 V, 15 mA
Acquisition on/off switchRemote acquisition enabled TTL, 5 V
Power output line5 V, 500 mA power output line (short-circuit protected)
Alarms3 TTL, 5 V, 15 mA
Analog output2 analog outputs (12 bits) ±5 V in 10 kΩ
Pace input5 V TTL pace input
DisplayDisplay size26.4 cm (10.4 in.) (diagonal)
Resolution800 pixels x 600 pixels
Brightness700 cd/m2
Number of colors16 million
TypeTFT LCD
Power SupplyBattery typeSmart Li-ion battery
Number of batteries1 or 2 (battery chamber accommodates two hot-swappable batteries)
Battery lifeMinimum 7 hours with two batteries
Environmental SpecificationsOperating temperature range-10 °C to 45 °C
(14 ºF to 113 ºF)
Storage temperature range-20 °C to 60 °C (-4 ºF to 140 ºF) with batteries
-20 °C to 70 °C (-4 ºF to 158 ºF) without batteries
Relative humidityMax. 70% RH at 45°C noncondensing
Ingress Protection RatingDesigned for IP66
Shockproof ratingDrop-tested according to MIL-STD-810G 516.6
MX2 Module CompatibilityMXU 4.1R8 and laterOMNI-M2-PA32128PR
MXU 4.0 and laterOMNI-M2-PA1664
OMNI-M2-PA16128
OMNI-M2-PA32128
OMNI-M2-UT-2CH
MXU 3.1 and MXU 4.1R12 and laterOMNI-M-UT-8CH

Phased Array Module Specifications (Applies to OMNI-M2 modules)

GeneralOverall dimensions (W x H x D)226 mm x 183 mm x 40 mm (8.9 in. x 7.2 in. x 1.6 in.)
Weight1.6 kg (3.5 lb)
Connectors1 Phased Array connector: Olympus PA connector
2 UT connectors: LEMO 00
Number of focal laws256
Probe recognitionAutomatic probe recognition
Pulser/ReceiverAperture32 elements*
Number of elements128 elements*
PulserPA ChannelsUT Channels
Voltage40 V, 80 V, and 115 V95 V, 175 V, and 340 V
Pulse widthAdjustable from 30 ns to 500 ns, resolution of 2.5 nsAdjustable from 30 ns to 1,000 ns; resolution of 2.5 ns
Pulse shapeNegative square pulseNegative square pulse
Output impedance (32:128PR model)35 Ω in pulse-echo mode
30 Ω in pitch-catch mode
< 30 Ω
Output impedance (all other models)25 Ω< 30 Ω
ReceiverPA ChannelsUT Channels
Gain0 dB to 80 dB, maximum input signal 550 mVp-p (full-screen height)0 dB to 120 dB maximum input signal 34.5 Vp-p (full-screen height)
Input impedance (32:128PR model)50 Ω in pulse-echo mode
90 Ω in pitch-catch mode
60 Ω in pulse-echo mode
50 Ω in pitch-catch mode
Input impedance (all other models)65 Ω60 Ω in pulse-echo mode
50 Ω in pitch-catch mode
System bandwidth0.5 MHz to 18 MHz (NOTE: The previously stated 0.6 MHz lower limit used a strict −3 dB attenuation for the cutoff frequency.)0.25 MHz to 28 MHz (-3 dB)
BeamformingScan typeSectorial and linear
Group quantityUp to 8
Data AcquisitionEffective digitizing frequencyUp to 100 MHz
Maximum pulsing rateUp to 10 kHz (C-scan)
Data ProcessingPA ChannelsUT Channels
Number of data pointsUp to 8,192
Real-time averaging2, 4, 8, 162, 4, 8, 16, 32, 64
RectifierRF, full wave, half wave , half wave –
Filtering3 low-pass, 3 band-pass, and 5 high-pass filters.3 low-pass, 6 band-pass, and 3 high-pass filters (8 low-pass filters when configured in TOFD)
Video filteringSmoothing (adjusted to probe frequency range)
Data VisualizationA-scan refresh rateReal time: 60 Hz
Data SynchronizationOn internal clock1 Hz to 10 kHz
On encoderOn 2 axes: from 1 to 65,536 steps
Programmable Time-Corrected Gain (TCG)Number of points32: One TCG curve per focal law
AlarmsNumber of alarms3
ConditionsAny logical combination of gates
Analog outputs2
  • Availability: 25 In Stock
  • Model: Omniscan MX2
  • Brand: Olympus

Write Review

Note: Do not use HTML in the text.

Brands List

  • API
  • Artec3D
  • BRUKER
  • CREAFORM
  • Easy-Laser
  • FARO
  • Fixturlaser
  • GE Inspection Technologies
  • GEOSLAM
  • GSSI
  • Hamar Laser
  • Hitachi
  • Leica Geosystem
  • MALA
  • NDT System
  • Olympus
  • PINPOINT LASER SYSTEM
  • Proceq
  • Radiodetection
  • SciAps
  • Sensors and Software
  • SKF
  • Sonatest
  • Thermo Fisher Scientific
  • Trimble
  • US Radar Inc
  • Waygate Krautkrämer
  • ZETEC