New Sonatest Masterscan D-70 Ultrasonic Flaw Detector - Sale !!

The Masterscan name has always assured the technician of robust instrument construction combined with exceptional performance. Features can be added and upgrades performed in the working environment, reducing downtime and increasing working flexibility. High levels of near surface resolution, penetrating power (450V pulser - square and spike) and excellent signal to noise ration are key functions in the Masterscan range. This instrument offers the inspector a fully capable and functional set of tools and software for inspection across all applications. Capabilities include encoded B-Scan, Advanced Thickness logging and Dryscan capability in a portable enclosure.
£1,665.93
Qty:

Overview

 

The Masterscan name has always assured the technician of robust instrument construction combined with exceptional performance. 

Features can be added and upgrades performed in the working environment, reducing downtime and increasing working flexibility. High levels of near surface resolution, penetrating power (450V pulser - square and spike) and excellent signal to noise ration are key functions in the Masterscan range.

This instrument offers the inspector a fully capable and functional set of tools and software for inspection across all applications. Capabilities include encoded B-Scan, Advanced Thickness logging and Dryscan capability in a portable enclosure.

Typical applications are Weld Fabrication, Corrosion Detection, Composite Inspection, Bond Testing, Forgings and Castings, Power Generation (including EMATS and general UT inspection).

Features

Reliable, Rugged & Robust

An instrument's ability to perform in harsh environments with proven reliability is an important aspect of flaw detector ownership and this is enhanced by the Masterscan's outstanding battery performance which is up to 18 hours from full charge. The Masterscan's enclosure is constructed using automotive grade impact resistant materials, offering excellent water resistance. Explosive Testing MIL810-G standards have been passed, together with environmental testing which has confirmed the instrument fully functioning at temperatures above 55ºC. The Masterscan D-70 has a colour transflective VGA display and maximum readability is achieved through adjustable brightness and the choice of 9 colour palettes, including black-on-white LCD emulation mode.

Advanced Defect Sizing Tools as Standard

Weld and pipe inspection are major applications for the Masterscan D-70 and they are equipped with the latest software tools for defect sizing. The use of integrated sizing software reduces analysis time and speeds inspection. Multiple standard sizing techniques are essential for service companies working to different customer standards, especially as service work becomes more international and operators are required to work to different codes.

UT-Lity Data Management Software

UT-Lity software provides everything you need to manage your inspection data. The standard version is FREE with every instrument and gives you the ability to view, move and manage Calibrations, A-Scans, B-Scans and Thickness Logs both on the instrument and on your PC. With UT-Lity you can also create customised inspection report templates, cut-n-paste information to other applications and create printable pdf documents.

  • Load, store, manage files both on the PC and on a connected flaw detector
  • Save, analyse, colour code and export thickness logging data to spreadsheets/asset management software
  • Update the Flaw Detector and Firmware as and when updates become available on our website

Sizing Techniques and Software Options include:

  • DAC (Standard)
  • Split DAC & DGS/AVG (Option)
  • TCG (Option)
  • Backwall Echo Attenuation (BEA) Option (requires TCG)
  • AWS (Option)
  • AVG/DGS (Option)
  • API (Option)
  • Interface Trigger (Option)
  • Corrosion Software (Option)
  • Dryscan Function (Option)

Masterscan D-70 Specifications

Test Range:0.04" - 787" (0-1mm up to 0-20,000mm) in steel at 5930m/s (19455f/s)
Velocity:256 - 16,000 m/s continuously variable
Probe:0 to 1000 μs
Delay:800" (0-20,000m) in steel at 5930m/s.
Gain:0 to 110dB adjustable in 0.1, 0.5, 1, 2, 6, 14 and 20dB steps.
Test Modes:Pulse echo and transmit/receive. Single Crystal, Double Crystal and Pitch-Catch.
Damping:50 and 400 ohm damping selectable.
Pulser:100-450V - ve spike and square wave. Pulse Width from 30nS to 2500nS. Rise/Fall times <5nS into 50R load.
P.R.F:Adjustable 5Hz to 6kHz. External sync also available.
Screen Update Rate:60Hz
Rectification:RF, Full wave, ve half-wave and -ve half-wave
Frequency Range:8 selectable filter bands.
  1. 100kHz - 500kHz
  2. 200kHz - 800kHz
  3. 0.4MHz - 1.6MHz
  4. 1.4MHz - 3.0MHz
  5. 3.0MHz - 8.0MHz
  6. 7.0MHz - 15.0MHz
  7. 9.0MHz - 21.0MHz
  8. 1.6MHz - 33.0MHz (Wideband)
  9. Additional tuned low frequency pre-amp with Dryscan option.
System Linearity:Vertical = 0.5% Full Screen Height (FSH). Horizontal /- 0.2% Trace Full Screen Width (FSW).
Reject (Selectable):Up to 80% Linear reject (removes baseline noise without affecting indication amplitude)
Or
Up to 50% Suppressive reject (increase zero offset and reduces amplitude of all echoes)
LED Warning when active.
Units:Inch (in), Metric (mm) or microseconds
Display:Color Transflective VGA (640 x 480) TFT
Display area: 116.16 x 87.2 mm (4.57 x 3.43 in).
A-Scan Area: 400 x 510 pixels (normal), 460 x 620 (FS).
Colors: 9 color options with variable brightness.
Gate Monitor:Two independent gates for measurement and monitoring. Start and width fully adjustable over the entire range of the instrument. Levels adjustable from 0% to 100%, positive or negative triggering on each gate with audible & visual alarms. Gate resolution is 5nS.
Zoom:Expands range and delay to cover the area set by Gate 1 start & width controls.
AGC:Automatic Gain Control automatically sets the signal in Gate 1 to a level between 10% and 90% FSH, tolerance between 5% and 20%.
Measurement Modes:
Mode 1:Signal monitor, Gate alarms can be active but no measurements are displayed.
Mode 2:Depth and amplitude of first signal in gate.
Mode 3:Echo-Echo distance measurements.
Mode 4:Trigonometric display of beam-path, surface distance (including X-offset) and depth of indication from the inspection surface together with echo amplitude. Curved surface correction can be applied for convex and concave surfaces. Half-skip can be indicated on screen.
Mode 5:Gate to Gate distance measurement.
Mode 6:Flank to Flank
Mode 7:Beam Angle, calculated from beam path, hole radius and hole center depth.
Measurement Display:Live display and updates on screen at 3 times per second. Large display of a single measurement available.
Contour:Trailing-Edge slew-rate control to reduce half cycles in rectified modes. Selectable from one of 6 levels.
Waveform Smoothing:Select from:
  1. None (both min and max values are displayed in the A-Scan)
  2. Fill (Min values set to baseline value, produces a solid A-Scan)
  3. Smooth (Min values ignored, produces a clear outline A-Scan)
Persistence:Causes previous A-scans to “fade out” at a user-determined rate.
Auto-Cal:Provides automatic calculation of velocity and probe zero from 2 reference echoes.
Reference Waveform:Displays a previously stored A-log in a color different from the active display: enabling a quick visual check of the differences.
Clock:Built in, battery-backed RTC keeps time and date. Visible on the status line, always stored with Panels, A-logs etc.
Internal Memory:4 GB storage available for A-scans, panels, T-logs, B-logs etc. 450,000 Panels, 200,000 A-Logs, 300,000 B Charts, 440,000 T-Logs.
Active Peak Memory:Retains all A-scans on screen for echo-dynamic pattern analysis, with the active A-scan displayed in a separate color.
Notes:Alphanumeric labelling for panel stores, A-logs, B-logs etc.
Display Freeze:Hold the current waveform on screen for off-line processing.
Language Support:Multiple languages are selectable from a list including:
English, French, Spanish, Russian, Chinese (Modern). Others are available on request.
Encoder Connection:Lemo min 4-pin connector (D70)
Video Output:Factory Option on D-70.
USB Connection:Internal storage shown as Memory Device.
Transducer Sockets:BNC or LEMO (factory option).
Power:Lithium Ion 14.4V battery pack. Typically 12 hours for D-70. Indication of battery charge status. Recharge time 3-4 hrs. Battery can be charged separately. Mains pack optional.
Charger:100-240 VAC, 50-60 Hz.
Environmental:Designed to meet IP67
Temperature:Operating: 14° to 131°F (-10° to 55°C)
Storage: -40° to 167°F (-40° to 75°C)
Size:6.77" x 9.37" x 2.75" (172 x 238 x 70mm) (HxwxD)
Weight:3.7 lbs. (1.7 kg) with battery
Warranty:2 year
Extended Warranty:Sonacover - extended 5 year warranty, including 4 calibrations.
Calibration Standards:EN12668-1:2010 (Detailed Specification available on request).
Standards:Vibration to 514.5-5 Proc 1 Annex C Fig 6
Shock 516.5 Proc 1 15g/6ms
Explosive atmospheres - MIL-STD 810G
Method 511.5 Procedure I


  • Availability: 18 In Stock
  • Model: Masterscan D-70
  • Brand: Sonatest

Write Review

Note: Do not use HTML in the text.

Brands List

  • API
  • Artec3D
  • BRUKER
  • CREAFORM
  • Easy-Laser
  • FARO
  • Fixturlaser
  • GE Inspection Technologies
  • GEOSLAM
  • GSSI
  • Hamar Laser
  • Hitachi
  • Leica Geosystem
  • MALA
  • NDT System
  • Olympus
  • PINPOINT LASER SYSTEM
  • Proceq
  • Radiodetection
  • SciAps
  • Sensors and Software
  • SKF
  • Sonatest
  • Thermo Fisher Scientific
  • Trimble
  • US Radar Inc
  • Waygate Krautkrämer
  • ZETEC